CONSTRUCTION
MACHINERY

Handheld dry drilling · Current DE-04B / DE23132 specification

DE04B handheld dry-coring system

Dekola’s brushless handheld dry-coring system, with a published 230 V/50 Hz, 1500 W specification, two speed/impact figures and a described 38 L extraction package. The quoted configuration and tool connections need confirmation together.

Match the quoted drill to DE23132

The parameter tab identifies a specific electrical version.

Official parameterPublished valuePurchase interpretation
Model / itemDE-04B / DE23132Match these to the returned specification and supplied identification.
Rated supply / input230 V / 50 Hz; 1500 WInput power is not a measured mechanical output. A different electrical version needs its own sheet.
No-load rotational speeds1500 / 3000 rpmNo-load values, not cutting speed under load or a production-rate guarantee.
No-load impact rates24,000 / 48,000 bpmImpact figures are separate from spindle rotation. Confirm mode/tool applicability in the manual.
Maximum hole diameter132 mmThe description calls this a handheld maximum; obtain applicable material/depth/mode conditions.
Head/drill net mass3.7 kgDoes not include the entire vacuum, hose, tools or shipping pack.
Spindle thread notationM18No pitch is supplied in this table. Obtain the controlled connection specification.

These figures were read directly from the model’s parameter tab. [1] The description adds brushless operation, two modes with micro-impact, soft start and a mechanical slip clutch. Those are supplier feature statements; no CivilEquip kickback, durability or drilling test is claimed.

Separate the drill limit from included tools

The stated maximum is not the size of each supplied bit.

Website-described standard set

  • Vacuum adaptor marked “M18-1-1/4UNC”.
  • Listed 52, 63 and 83 mm hammer-type drilling bits.
  • 38 L multifunction wet/dry vacuum, described with HEPA filtration, one-button start and automatic dust shaking.

The source describes these as standard. Confirm the actual itemised scope and destination configuration on the quote. [1]

Connection and revision checks

Ask for the adaptor’s controlled thread drawing, bit connection and mode instructions. Do not infer an M18 pitch or silently convert the written adaptor notation. A compatible-looking photo does not establish a matched connection.

A 132 mm maximum does not imply a 132 mm bit is included: the listed standard diameters are 52/63/83 mm. If your hole needs another diameter or depth, require the exact tool reference and supported operating conditions.

No stand is identified in the DE04B described set. The manufacturer separately lists DE08B+DS-10 and DE10B+DS-10. [2] Do not transfer those stands into this handheld offer without an approved combination.

Define dry drilling as a complete site task

Dekola describes DE04B for domestic renovation and says its dry-drilling package can cut reinforced concrete without water. [1] That is a supplier application claim, not a verified result for every reinforcement pattern, hole depth or operating orientation.

  1. Hole and materialGive diameter, depth, drilling direction, concrete/reinforcement information and hole count. Ask the supplier to identify the matched bit and permitted mode.
  2. Power and handlingMatch the published 230 V/50 Hz version to site supply and obtain the electrical/manual requirements. Assess the whole assembly and access, not only the 3.7 kg head.
  3. Extraction and work environmentIdentify the extractor and hose/interface arrangement for the job. The manufacturer’s HEPA description alone does not establish task exposure or a complete dust-control assessment.

HSE’s CN3 guidance addresses hand-held drilling/coring with respiratory protection alongside extraction and/or water suppression. [3] The responsible site assessor must select and review appropriate controls for the actual task. This page does not certify the supplied vacuum or provide a site-specific safe operating procedure.

Approve the system documents with the order

Request the current DE23132 datasheet/manual, exact vacuum specification, matched tool references and connection drawings. Ask for the permitted diameter/depth/material conditions and maintenance/consumable instructions. If an export, dealer or alternate-voltage set differs from the website, record the differences before price approval.

The image currently stored in this directory is a historical manufacturer catalogue image. It is not proof that the current drill/accessory revision looks identical. Require supplied identification, item list, inspection/acceptance scope, destination documents and shipping mass/dimensions for the actual package.

Does 1500 W establish drilling productivity?

It is published input power. No cutting-time, feed-rate or production-rate test is established here. Request a supported application response for the actual hole and tool.

Is the vacuum’s 38 L volume a dust-control performance rating?

No. Container volume is distinct from airflow, filtration/system classification and task exposure. Obtain the extractor specification and a competent site assessment.

Request the drill, tools and extraction together

Editable procurement record. Review the separate form before submission; no supplier is contacted by copying.

Sources & review

  1. DE04B description and parameter tab ↗

    Current text and clicked parameter tab: DE-04B/DE23132, supply/input power, no-load figures, diameter, head mass and spindle. Also described vacuum, adaptor and bit package. Manufacturer claims, not CivilEquip tests.

    2026-10-11
  2. Dekola drill and stand-combination list ↗

    Separate DS-10 combination names; no stand assumed included with DE04B.

    2026-10-11
  3. HSE construction-silica guidance, CN3 ↗

    Task-specific drilling/coring guidance links extraction/water suppression with respiratory protection. Does not assess or certify this product.

    2026-10-11

Specifications come from the manufacturer’s published information and the sources above; buying advice is written by CivilEquip with AI assistance. Ask the manufacturer to confirm the data for your configuration. Editorial policy · Report a correction.